How to Prime Berkey® Filters (Phoenix, Black Berkey & PF-2)

Priming uses clean, cold water to push trapped air out of new or dry filter pores and flush loose process dust before your first batch. Filter elements will not flow properly if they are not primed first. Follow the official steps below for your primer and filter type.

How do I prime Phoenix or Black Berkey filters with the PrimeEasy Universal Primer?

Every Phoenix filter set includes a PrimeEasy™ Universal Primer designed to stretch over both larger and smaller faucet spouts.

  1. Dry the faucet and primer: Make sure the faucet head and the inside of the PrimeEasy™ primer are dry so you get a tight seal and a solid grip.
  2. Fit the primer onto the faucet: Stretch the larger end of the primer up and over the faucet spout as far as it will go.
  3. Insert the filter stem: Hold the element in one hand and push its threaded stem up into the smaller end of the primer as far as it will go.
  4. Turn on cold water slowly: Keep one hand holding the primer on the faucet head and slowly turn on cold water only. Gradually increase the flow while keeping pressure low. Turning the water too high can make water spray or leak where the primer seals on the faucet. (If you are using an older blue Universal Primer and it inflates like a bulb, reduce water pressure right away.)
  5. Rub and flush for 1 minute: Once beads of water sweat out of the outside of the filter, keep water running and rub the outside of the element with your hand for 1 minute until the element looks saturated and the water runs clear. Water may look discolored at first as excess process dust exits.
  6. Set aside cleanly: Place each primed wet element in a clean bowl or sink while you prime the remaining elements.

How do I prime filters without a rubber primer (using the sealing washer or tan priming button)?

If your faucet does not fit the PrimeEasy™ primer, or you have a Black Berkey® tan priming button, you can prime using the element's sealing washer or priming button:

  1. Remove the wing nut and sealing washer from the element stem. Turn the wing nut upside down (flat side facing up) and screw it onto the stem until the top of the wing nut sits about 1/8 inch from the top of the stem's threads.
  2. Place the sealing washer (or tan priming button) on top of the upside-down wing nut so the washer sits slightly higher than the top of the stem.
  3. Hold the threaded stem between your fingers and press the washer or priming button firmly up against the faucet spout.
  4. Slowly turn on cold water and gradually increase pressure while holding the seal against the faucet until water beads across the outside of the element. Keep running water for 1 minute until the water runs clear.
  5. Before installing the element in your upper chamber, remove the wing nut, leave the sealing washer in place on the stem, and flip the wing nut right-side up when you tighten it underneath.

How do I prime Berkey filters off-grid without a faucet?

  • Using the PrimeEasy™ Universal Primer and a water bottle: Use clean, filtered water and a flexible or collapsible bottle (16 oz or larger). Remove the bottle lid, stretch the wider end of the PrimeEasy™ primer over the top of the bottle as far as possible, and push the filter stem into the smaller end. Turn the assembly upside down in a sink or area that can get wet so the filter rests on a flat surface with the bottle above it, then squeeze water from the bottle into the filter until beads of water appear across the element. Repeat if needed.
  • Using a Black Berkey Primer™ hand pump: New Millennium Concepts also makes a handheld priming pump (sold separately) that primes Black Berkey® elements without a faucet or hose connection.

How do I purge optional Berkey PF-2 filters?

Berkey PF-2™ fluoride and arsenic elements contain fine process dust that can give water a bitter taste if they are not purged before use. Never boil PF-2 elements and use cold water only—hot water can create unsafe water temperatures.

Method A — Using the tan rubber purging button (included with PF-2):

  1. Leave the end caps on while you remove any stickers and wash the outside of each PF-2 with mild dish soap.
  2. With clean hands, remove both end caps.
  3. Place the tan rubber purging button on one end of the PF-2, lining up the hole in the button with the hole in the element.
  4. Press the purging button against the sink faucet (resting a thumb on top of the faucet helps hold a seal) and turn on cold water gently so water fills the PF-2 and flows out the opposite end.
  5. Let water discharge for at least 20 seconds or until it runs clear, whichever is longer.
  6. Flip the PF-2 around and repeat on the other end.

Method B — Using a PF-2 adapter with a PrimeEasy™ or Universal Primer:

  1. Attach the primer to the faucet, screw the fluoride element adapter into the threaded end of the PF-2, and gently press the adapter into the primer.
  2. Hold the element with one hand and slowly turn on cold water to a moderate flow (reduce immediately if the primer inflates).
  3. Cover the bottom end of the PF-2 with a finger (or cap) and let water fill it for about 30 seconds, then turn the water off. Remove the element, cover both ends, and shake vigorously for 1 minute.
  4. Reconnect to the primer and run cold water at low pressure, increasing slowly until a steady stream runs clear (about 2–3 minutes).

Installing purged PF-2 elements: Place the upper chamber upside down on a counter. Screw the larger, threaded end of each purged PF-2 onto the stem of an already-primed upper element eight full revolutions—no more, as turning further can damage the internal media screen. Place the upper chamber onto the lower chamber, filter one batch of water, and discard that first batch. (It can take up to 10 batches for trace process dust to clear completely; if dust persists, repeat the purge.)

What should happen after I install primed filters?

  • Depending on how fully primed the elements are, water may start dripping right away or take up to 15 minutes to begin dripping into the lower chamber.
  • Maximum flow rate is reached after the first 12–24 hours of use as tiny air pockets leave the pores.
  • It is normal for a few inches of water to remain in the upper chamber, because gravity cannot push water below the base of the elements.
  • Never allow wet filter elements to freeze—freezing water expands and can crack the elements.
  • After installing or replacing upper elements, run the red food coloring seal test (always remove PF-2 elements first before testing).

What if water leaks at the faucet or my filters still will not flow?

If water sprays at the faucet, dry both surfaces and lower the water pressure. If you are reinstalling older elements that stopped flowing, Berkey Support notes you can scrub the outside of Black Berkey® elements gently with a clean Scotch-Brite® pad under cold running water and re-prime them. If you are still stuck, call us—we are happy to walk through it with you.

More owner guides: Berkey leak fixes · What's in my Berkey? owner guide · How many PF-2 filters do I need? · Compatibility chart · Shop Phoenix filters

Still not sure?

Berkey Products is operated by an Authorized Berkey® Dealer. Call 1-877-770-6685 or email sales@berkeyproducts.com, Monday–Friday, 9 a.m.–5 p.m. ET.

Free shipping. Orders ship the next business day; delivery takes 3–5 business days. Continental U.S. only; we can't ship to Iowa or California.